TSO'D  400HZ STATIC INVERTERS

100 TO 350 VA

SPC 10The SPC-10( ) Series static inverter utilizes solid state circuitry to convert 28 VDC to 115 VAC, 400 Hz sine wave power. Design features include pulse-width modulated square to sine wave power conversion permitting light weight and reliable operation.

The SPC-10( ) Series are capable of delivering an overload of 150% of rated current for a duration not less than five minutes under all environmental conditions.

 

Specifications:
Model:
SPC-10( ) SPC-10(F) & (N) SPC-10(H)
Input Voltage(VDC):
Normal:
Abnormal:
22 to 32
20 to 37
24 to 32
18 to 36.4
24 to 32
20 to 36.4
Input Current (ADC):
@ 28 VDC IN
4.8 10.6 15.0
Output Power  (Total):
115 VAC / 26 VAC
100 VA
100 VA / 60 VA
250 VA
250 VA / 150 VA
350 VA
350 VA / 150 VA
Efficiency  (%) :
75 to 78 82 min. 80 min.
Weight:
5.2 lbs. 5.5 lbs. 5.6 lbs.
Output Voltage: 115 VAC and / or 26 VAC
Phase/Waveform: Single / Sine Wave
Frequency: 400 Hz ± 1%
Amplitude Distortion: Less than 7% (3% Typ.)
Power Factor: .8 to -.95
Input Overvoltage: Operate up to 37 VDC input while supplying full rated VA output   power.  Output voltage under this condition is 115 VAC +5%, 7%.
Input Transient Protection: Withstands transients of 88 volts 1 mSec on the 28 VDC input line.
Overload & Short Circuit Protection: Withstands without damage or degradation load exceeding 150% of  rated output to an output dead short.Inverter delivers rated output on removal of above conditions.
Altitude: 55,000 ft.
Temperature: -65°F to +160°F (-55°C to +71°C)
Humidity: Tested to greater than 95% for 10 days, temperature was cycled between 75°F to 160°F
Environmental: Qualified to meet RTCA paper D0-160 Env. Cat. D2BR--

 

PINS SPC-10( ) SPC-10(D) SPC-10(F) SPC-10(H) SPC-10(N)
A 28 VDC INPUT 28 VDC INPUT REMOTE ON/OFF REMOTE ON/OFF FAULT MONITOR
B DC GROUND 115 VAC OUTPUT 115 VAC OUTPUT 115 VAC OUTPUT 28 VDC INPUT
C AC RETURN AC RETURN AC RETURN AC RETURN PHASE LOCK
D 115 VAC OUTPUT DC GROUND ON/OFF RETURN ON/OFF RETURN DC GROUND
E NO CONNECTION REMOTE ON/OFF NO CONNECTION FAULT MONITOR REMOTE ON/OFF
F 26 VAC OUTPUT FAULT MONITOR PHASE LOCK PHASE LOCK AC RETURN
G   26 VAC OUTPUT 26 VAC OUTPUT 26 VAC OUTPUT 115 VAC OUTPUT
H     28 VDC INPUT 28 VDC INPUT 26 VAC OUTPUT
I     DC GROUND DC GROUND  
J         ON/OFF RETURN
MATE MS3106B14S-6S MS3106B18-9S MS3106B20-16S MS3106B20-16S MS3476L14-9S